C00008 | original application|control source, 16 parameter reference, Terminal assignment of the control modes 10 – Lenze 8400 User Manual
Page 744

16
Parameter reference
16.2
Parameter list | C00008
744
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Terminal assignment of the control modes 10 ... 16
C00008
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable / Reset of error message
DI1
Fixed setpoint 1/3
Change of direction of
rotation
Fixed setpoint 1/3
DI2
Fixed setpoint 2/3
Activate manual DC-
injection braking (DCB)
Fixed setpoint 2/3
DI3
Activate manual DC-injection
braking (DCB)
Quick stop
Motor potentiometer:
Increase speed
CW rotation quick stop
DI4
Change of direction of rotation
Motor potentiometer:
Decrease speed
CCW rotation quick stop
DI5
-
-
-
-
DI6
-
-
-
-
A1U
Main speed setpoint (10 V ≡ 100 % reference speed)
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable / Reset of error message
DI1
-
-
Positive limit switch
-
DI2
-
-
Negative limit switch
-
DI3
Positive limit switch
-
-
-
DI4
Negative limit switch
Positioning profile, array bit (valency 2)
Quick stop
DI5
Positioning profile,
array bit (valency 2)
Positioning profile, array bit (valency 1)
Positioning profile,
array bit (valency 2)
DI6
Start of profile generation
A1U
Main speed setpoint (10 V ≡ 100 % reference speed)
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable
Controller enable / Reset of error message
DI1
Fixed setpoint 1/3
Stop function 1
Fixed setpoint 1/3
DI2
Fixed setpoint 2/3
Stop function 2
Selection: Pre-switch off 1
Fixed setpoint 2/3
DI3
Reset error message
CW rotation quick stop
Selection: Switch-off position 1
CW rotation quick stop
DI4
Change of direction of
rotation
CCW rotation quick stop
Selection: Switch-off position 2
CCW rotation quick stop
DI5
-
-
Stop function 2
-
DI6
-
-
Selection: Pre-switch off 2
-
A1U
Main speed setpoint (10 V ≡ 100 % reference speed)
Parameter | Name:
C00008 | Original application|control source
Data type: UNSIGNED_16
Index: 24567
d
= 5FF7
h
Display of the originally selected technology application and the originally selected control mode.
• This parameter shows the selection that was set with
before a change in the I/O level or the
application level was carried out.
• For diagnostic purposes, this display serves to determine whether there is a standard interconnection in the
controller or a change carried out by the user.
Selection list
(read only)
Info
0 Free|Free
Application: Interconnection has been changed.
I/O level: Interconnection has been changed.
10 Free|Terminal0
Application: Interconnection has been changed.
I/O level: "Terminals 0" control mode