C00653 | Sensibility - Setpoint feedforward control
Data type: UNSIGNED_8
Index: 23922
d
= 5D72
h
From version 12.00.00
Selection of the sensitivity of the differential setpoint feedforward control
• Depending on the selection, the number of indicated higher-order bits is evaluated.
Note:
The most significant bit determines the sign of the value, the remaining bits determine the numerical value.
Selection list
Info
0 Inactive
1 15 bits
Bit 0 ... bit 14 are evaluated
2 14 bits
Bit 0 ... bit 13 are evaluated
3 13 bits
Bit 0 ... bit 12 are evaluated
4 12 bits
Bit 0 ... bit 11 are evaluated
5 11 Bit
Bit 0 ... bit 10 are evaluated
6 10 Bit
Bit 0 ... bit 9 are evaluated
7 9 Bit
Bit 0 ... bit 8 are evaluated
Subcodes
Lenze setting
Info
C00653/1
0: Inactive
Sensibility - Setpoint feedforward control
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00654 | Source of diff. setpoint feedforward control
Data type: UNSIGNED_8
Index: 23921
d
= 5D71
h
From version 12.00.00
Selection of the process signal for the setpoint feedforward control
Selection list
Info
0 nSpeedSetValue_a
1 nSpeedSetValueInertia_a
The new process signal nSpeedSetValueInertia_a at
SB
can be used to define any input
value (e.g. position or process controller setpoint) for
torque feedforward control.
Subcodes
Lenze setting
Info
C00654/1
0: nSpeedSetValue_a
Source of diff. setpoint feedforward control
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00660 | L_FixSet_a_1: Analog values
Data type: INTEGER_16
Index: 23915
d
= 5D6B
h
From version 02.00.00
FB
: Setting of the fixed values
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00660/1
0.00 %
Fixed value 0 ... 15
C00660/...
C00660/16
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100