Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

871

16

Parameter reference

16.2

Parameter list | C00653

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00653

C00654

C00660

Parameter | Name:

C00653 | Sensibility - Setpoint feedforward control

Data type: UNSIGNED_8

Index: 23922

d

= 5D72

h

From version 12.00.00

Selection of the sensitivity of the differential setpoint feedforward control

• Depending on the selection, the number of indicated higher-order bits is evaluated.

Note:

The most significant bit determines the sign of the value, the remaining bits determine the numerical value.
Selection list

Info

0 Inactive
1 15 bits

Bit 0 ... bit 14 are evaluated

2 14 bits

Bit 0 ... bit 13 are evaluated

3 13 bits

Bit 0 ... bit 12 are evaluated

4 12 bits

Bit 0 ... bit 11 are evaluated

5 11 Bit

Bit 0 ... bit 10 are evaluated

6 10 Bit

Bit 0 ... bit 9 are evaluated

7 9 Bit

Bit 0 ... bit 8 are evaluated

Subcodes

Lenze setting

Info

C00653/1

0: Inactive

Sensibility - Setpoint feedforward control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00654 | Source of diff. setpoint feedforward control

Data type: UNSIGNED_8

Index: 23921

d

= 5D71

h

From version 12.00.00

Selection of the process signal for the setpoint feedforward control
Selection list

Info

0 nSpeedSetValue_a
1 nSpeedSetValueInertia_a

The new process signal nSpeedSetValueInertia_a at

SB

LS_MotorInterface

can be used to define any input

value (e.g. position or process controller setpoint) for

torque feedforward control.

Subcodes

Lenze setting

Info

C00654/1

0: nSpeedSetValue_a

Source of diff. setpoint feedforward control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00660 | L_FixSet_a_1: Analog values

Data type: INTEGER_16

Index: 23915

d

= 5D6B

h

From version 02.00.00

FB

L_FixSet_a_1

: Setting of the fixed values

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C00660/1

0.00 %

Fixed value 0 ... 15

C00660/...
C00660/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100