Function library
18.2
System blocks | LS_ServiceSwitch
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.2.32
LS_ServiceSwitch
This system block provides the switching states of the optional service switch in the FB Editor.
• Which outputs are effective depends on the service switch type available (service switch
without/with protective function, service switch with operating unit)
• If no service switch is available, all outputs have to be permanently set to FALSE.
Outputs
Identifier
Data type
Meaning in case of TRUE
bSwitch_left
BOOL
Operating unit: Left switch position
bSwitch_right
BOOL
Operating unit: Right switch position
bSwitch_middle
BOOL
Operating unit: Central switch position
bSwitch_Manual
BOOL
Operating unit: Key-operated switch in "manual" position
bMainOff
BOOL
Service switch: "Off" switch position or overcurrent protective function has been
triggered
Note!
For flexible customer solutions, the user has to configure the system block for the
desired functionality correctly.