Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
879
16
Parameter reference
16.2
Parameter list | C00701
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00701
C00700/15
0: Not connected
: nGPCompareIn2_a
Input for comparison operation - analog signal 2
C00700/16
0: Not connected
: nVoltageAdd_a
Input for additive voltage boost
C00700/17
0: Not connected
: nPIDInfluence_a
Input for influence signal of PID controller correcting
variable
C00700/18
0: Not connected
: nPIDSetValue_a
Input for PID controller setpoint
C00700/19
0: Not connected
: nPWMAngleOffset
Input for pulse width modulation phase offset
C00700/20
0: Not connected
: nBoost_a
Input for additional setpoint for motor voltage at speed
= 0
C00700/21
0: Not connected
: wSMCtrl
Interface to the optional safety system
C00700/22
0: Not connected
Reserved
C00700/23
0: Not connected
Reserved
C00700/24
0: Not connected
Reserved
C00700/25
0: Not connected
Reserved
C00700/26
0: Not connected
: wFreeIn1
Input for user signal 1
C00700/27
0: Not connected
: wFreeIn2
Input for user signal 2
C00700/28
0: Not connected
: wFreeIn3
Input for user signal 3
C00700/29
0: Not connected
: wFreeIn4
Input for user signal 4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00700 | LA_NCtrl: Analog connection list
Data type: UNSIGNED_16
Index: 23875
d
= 5D43
h
Parameter | Name:
C00701 | LA_NCtrl: Digital connection list
Data type: UNSIGNED_16
Index: 23874
d
= 5D42
h
Connection parameters for "Actuating drive speed" application: Binary inputs
• Selection of the binary output signals to be connected to the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00701/1
0: Not connected
: bCInh
Control input for setting controller inhibit
C00701/2
16008: LS_DigitalInput: bCInh
: bFailReset
Control input for error acknowledgement
C00701/3
0: Not connected
: bSetQuickstop
Control input for quick stop request
C00701/4
16002: LS_DigitalInput: bIn3
: bSetDCBrake
Control input for DC-injection braking request