16 parameter reference – Lenze 8400 User Manual
Page 1092

16
Parameter reference
16.3
Table of attributes
1092
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Brake resistor overload threshold
Linear value
24003
5DC3
E
1
UNSIGNED_8
1
Resp. to brake resist. overtemp.
Selection list
24001
5DC1
E
1
UNSIGNED_8
1
SC: Field feedforward control
Linear value
23999
5DBF
E
1
UNSIGNED_16
1
SC: Vp field weakening controller
Linear value
23998
5DBE
E
1
UNSIGNED_16
10000
SC: Tn field weakening controller
Linear value
23997
5DBD
E
1
UNSIGNED_16
10
Resp. to max. speed/output freq. reached
Selection list
23996
5DBC
E
1
UNSIGNED_8
1
Resp. to operating system error
Selection list
23995
5DBB
A
1
UNSIGNED_8
1
Resp. to LS_SetError_x
Selection list
23994
5DBA
A
8
UNSIGNED_8
1
Resp. to heatsink temp.> shutdown temp.
-5°C
Selection list
23993
5DB9
E
1
UNSIGNED_8
1
Resp. to motor overtemp. PTC
Selection list
23990
5DB6
E
1
UNSIGNED_8
1
Resp. to encoder open circuit HTL
Selection list
23989
5DB5
E
1
UNSIGNED_8
1
Resp. to brake resist. overtemp. PTC
Selection list
23988
5DB4
A
1
UNSIGNED_8
1
Resp. to max. speed at switching freq.
Selection list
23987
5DB3
E
1
UNSIGNED_8
1
Resp. to switch. frequency red.
Selection list
23985
5DB1
E
1
UNSIGNED_8
1
Resp. to CAN bus connection
Selection list
23983
5DAF
A
5
UNSIGNED_8
1
Resp. to CANx_IN monitoring
Selection list
23982
5DAE
A
3
UNSIGNED_8
1
Resp. to control word error
Selection list
23981
5DAD
A
2
UNSIGNED_8
1
MCK: Resp. to MCK error
Selection list
23980
5DAC
A
15
UNSIGNED_8
1
Resp. to motor phase failure
Selection list
23978
5DAA
E
1
UNSIGNED_8
1
Resp. to I/O monitoring
Selection list
23977
5DA9
A
4
UNSIGNED_8
1
Motor phase failure threshold
Linear value
23976
5DA8
E
1
INTEGER_16
100
Resp. to DC bus voltage
Selection list
23975
5DA7
A
1
UNSIGNED_8
1
Delayed resp. to fault: DC bus overvoltage Linear value
23974
5DA6
A
1
UNSIGNED_16
1000
Resp. to earth fault
Selection list
23973
5DA5
E
1
UNSIGNED_8
1
Resp. to motor overload (I²xt)
Selection list
23969
5DA1
E
1
UNSIGNED_8
1
Resp. to max. freq. feedb. DIG12/56
Selection list
23968
5DA0
E
1
UNSIGNED_8
1
Resp. to maximum torque
Selection list
23967
5D9F
E
1
UNSIGNED_8
1
Resp. to maximum current
Selection list
23966
5D9E
E
1
UNSIGNED_8
1
System connection list: 16-bit
Selection list
23955
5D93
A
105 UNSIGNED_16
1
System connection list: Bool
Selection list
23954
5D92
A
181 UNSIGNED_16
1
System connection list: Angle
Selection list
23953
5D91
A
24
UNSIGNED_16
1
L_Limit 1-2: Min/Max
Linear value
23945
5D89
A
4
INTEGER_16
100
L_LimitPhi 1-3: Min/Max
Linear value
23944
5D88
A
6
INTEGER_32
1
L_NSet_1: Max. skip freq.
Linear value
23943
5D87
A
3
INTEGER_16
100
L_NSet_1: Min. skip freq.
Linear value
23942
5D86
A
3
INTEGER_16
100
L_NSet_1: wState
Bit coded
23941
5D85
E
1
UNSIGNED_16
1
L_NSet_1: nMaxLimit
Linear value
23940
5D84
E
1
INTEGER_16
100
L_NSet_1: nMinLimit
Linear value
23939
5D83
E
1
INTEGER_16
100
L_NSet_1: Output blocking zones
Linear value
23938
5D82
E
1
INTEGER_16
100
L_NSet_1: Output ramp rounding
Linear value
23937
5D81
E
1
INTEGER_16
100
L_NSet_1: Output add.value
Linear value
23936
5D80
E
1
INTEGER_16
100
L_NSet_1: nNOut_a
Linear value
23935
5D7F
E
1
INTEGER_16
100
Resp. to PLI monitoring
Selection list
23932
5D7C
A
1
UNSIGNED_8
1
L_Arithmetik 3-5: Function
Selection list
23925
5D75
A
3
UNSIGNED_8
1
Sensibility - Setpoint feedforward control
Selection list
23922
5D72
A
1
UNSIGNED_8
1
Source of diff. setpoint feedforward
control
Selection list
23921
5D71
A
1
UNSIGNED_8
1
L_FixSet_a_1: Analog values
Linear value
23915
5D6B
A
16
INTEGER_16
100
L_FixSet_w_1: Fixed values
Linear value
23914
5D6A
A
16
UNSIGNED_16
1
L_FixSet_w_2: Fixed values
Linear value
23913
5D69
A
16
UNSIGNED_16
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)