C01093 - ls_parreadwrite 1-6: arithmetic mode, C01094 - ls_parreadwrite 1-6: numerator, 16 parameter reference – Lenze 8400 User Manual
Page 985

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
985
16
Parameter reference
16.2
Parameter list | C01093
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01093
C01094
Parameter | Name:
C01093 - LS_ParReadWrite 1-6: Arithmetic mode
Data type: UNSIGNED_8
Index: 23482
d
= 5BBA
h
From version 06.00.00
allows for easy arithmetic conversion of the process value to be written or which
was read into the format of the target parameter via parameterisable factors and without the need for an
additional arithmetic FB.
Selection list
0 No arithmetic
1 In16Bit: LW=+/-32767
2 In16Bit: HW=+/-; LW=0..65535
3 In32Bit: HW_LW=+/-2147483647
Subcodes
Lenze setting
Info
C01093/1
0: no arithmetic
: Arithmetic mode
C01093/2
0: no arithmetic
: Arithmetic mode
C01093/3
0: no arithmetic
: Arithmetic mode
C01093/4
0: no arithmetic
: Arithmetic mode
C01093/5
0: no arithmetic
: Arithmetic mode
C01093/6
0: no arithmetic
: Arithmetic mode
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01094 - LS_ParReadWrite 1-6: Numerator
Data type: INTEGER_16
Index: 23481
d
= 5BB9
h
From version 06.00.00
: Factor (numerator) for internal conversion in arithmetic modes 1 ... 3.
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C01094/1
1
: Numerator
C01094/2
1
: Numerator
C01094/3
1
: Numerator
C01094/4
1
: Numerator
C01094/5
1
: Numerator
C01094/6
1
: Numerator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1