C00356 | can time settings, C00357 | can monitoring times, C00358 | canx_out data length – Lenze 8400 User Manual
Page 813: C00357/1, C00357/2, C00357/3, C00357/4, C00356/1, C00356/5, C00358/1

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
813
16
Parameter reference
16.2
Parameter list | C00356
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00356
C00357
C00358
Parameter | Name:
C00356 | CAN time settings
Data type: UNSIGNED_16
Index: 24219
d
= 5E9B
h
Different time settings for the CAN interface
Setting range
(min. value | unit | max. value)
0
ms
65000
Subcodes
Lenze setting
Info
C00356/1
3000 ms
CAN delay boot-up - operat.
• Delay time for NMT state change from "Boot-up" to
"Operational".
C00356/2
0 ms
CAN2_OUT cycle time
C00356/3
0 ms
CAN3_OUT cycle time
C00356/4
0 ms
CANx_OUT operat. - 1.transmit
• When the "Operational" NMT status is reached, the
delay time set here is started. After the delay time has
been elapsed, the PDOs CAN2_OUT and CAN3_OUT
are sent for the first time.
C00356/5
0 ms
CAN1_OUT cycle time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00357 | CAN monitoring times
Data type: UNSIGNED_16
Index: 24218
d
= 5E9A
h
Mapping of the RPDO event time (see DS301 V4.02)
• If a value unequal to "0" is entered, the RPDO is not expected before the set time has expired.
• If the RPDO is not received within the expected time, the response set in
will be triggered.
Setting range
(min. value | unit | max. value)
0
ms
65000
Subcodes
Lenze setting
Info
C00357/1
3000 ms
CAN1_IN monitoring time
C00357/2
3000 ms
CAN2_IN monitoring time
C00357/3
3000 ms
CAN3_IN monitoring time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00358 | CANx_OUT data length
Data type: UNSIGNED_8
Index: 24217
d
= 5E99
h
Setting of the data length for TX PDOs
Setting range
(min. value | unit | max. value)
1
8
Subcodes
Lenze setting
Info
C00358/1
8
CAN1_OUT data length
C00358/2
8
CAN2_OUT data length
C00358/3
8
CAN3_OUT data length
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1