C00222 | l_pctrl_1: vp, C00223 | l_pctrl_1: tn, C00224 | l_pctrl_1: kd – Lenze 8400 User Manual
Page 793: C00225 | l_pctrl_1: maxlimit, C00226 | l_pctrl_1: minlimit, T in, C00222, In percent, C00223, C00224

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
793
16
Parameter reference
16.2
Parameter list | C00222
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00222
C00223
C00224
C00225
C00226
Parameter | Name:
C00222 | L_PCTRL_1: Vp
Data type: INTEGER_16
Index: 24353
d
= 5F21
h
FB: Gain factor Vp for the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.1
500.0 1.0
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00223 | L_PCTRL_1: Tn
Data type: UNSIGNED_16
Index: 24352
d
= 5F20
h
FB: Reset time Tn for the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
20
ms
6000 400 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00224 | L_PCTRL_1: Kd
Data type: UNSIGNED_16
Index: 24351
d
= 5F1F
h
FB: Derivative-action coefficient Kd for the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
5.0 0.0
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00225 | L_PCTRL_1: MaxLimit
Data type: INTEGER_16
Index: 24350
d
= 5F1E
h
FB: Maximum output value of the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 199.99 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00226 | L_PCTRL_1: MinLimit
Data type: INTEGER_16
Index: 24349
d
= 5F1D
h
FB: Minimum output value of the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 -199.99 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100