C02843
C02844
C02845
Parameter | Name:
C02843 | FreqInxx: Gain
Data type: INTEGER_16
Index: 21732
d
= 54E4
h
Gain for digital frequency inputs
Using DI1(5) and DI2(6) as frequency inputs
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C02843/1
100.00 %
FreqIn12: Gain
C02843/2
100.00 %
FreqIn56: Gain
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02844 | FreqIn12: Function
Data type: UNSIGNED_8
Index: 21731
d
= 54E3
h
From version 06.00.00
Output of the encoder position of the DI1/DI2 frequency input
Selection list
0 Loading with level
1 Loading with edge
2 Loading with level + reset
Subcodes
Lenze setting
Info
C02844/1
0: Loading with level
FreqIn12: PosIn function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02845 | FreqIn12: PosIn comparison value
Data type: INTEGER_32
Index: 21730
d
= 54E2
h
From version 06.00.00
Output of the encoder position of the DI1/DI2 frequency input
Setting range
(min. value | unit | max. value)
Lenze setting
0
Incr.
2147418112 0 incr.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1