beautypg.com

18 function library – Lenze 8400 User Manual

Page 1386

background image

18

Function library

18.1

Function blocks | L_ProcessCtrl_1

1386

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

bReset

BOOL

Reset entire control

TRUE All outputs are reset to 0.

nInfluence_a

INT

Proportional evaluation of the controller correcting variable nOutRed_a

• Scaling: 16384 ≡ 100 % controller correcting variable (nOut_a)

Identifier

Data type

Value/meaning

nOut_a

INT

Controller correcting variable

• Internal limitation to ±16384 (±100 %)

nOutRed_a

INT

Controller correcting variable (evaluated by nInfluence_a)

nDeviation_a

INT

System deviation

• Internal limitation to ±32767 (±199.99 %)

nDComponent

INT

D component of the rate action

• Internal limitation to ±16384 (±100 %)

Parameter

Possible settings

Info

C01053/1

0.000

s

30.000 Acceleration/deceleration time of

the setpoint ramp generator

• Lenze setting: 0.000 s

C01053/2

0.000

s

30.000 Filter time constant for actual

controller value

• Lenze setting: 0.000 s

C01053/3

0.000

s

30.000 Rate time for actual controller value

• Lenze setting: 0.000 s

C01053/4

0.000

s

30.000 Controller reset time

• Lenze setting: 1.000 s

C01053/5

0.000

s

30.000 Controller rate action

• Lenze setting: 0.000 s

C01054/1

0.00

%

199.99 Gain of the system deviation in the

range of reduced sensitivity

• Lenze setting: 100.00 %

C01054/2

0.00

%

199.99 Area of system deviation with

reduced gain/sensitivity

• Lenze setting: 0.00 %

C01055/1

Limitation of the controller

correcting variable to the positive

area

False Limitation not active.

(Lenze setting)

True Limitation active.

C01056/1

0.00

100.00 Controller gain

• Lenze setting: 0.10

Identifier

Data type

Information/possible settings