C01245 | mck: target detection - positions, C01246 | mck: select signal source, C01251 | mck: acceleration stop – Lenze 8400 User Manual
Page 1010: C01251, If th, C01245/3, C01245/1, C01246/1, C01246/2, C01251/1

16
Parameter reference
16.2
Parameter list | C01245
1010
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01245
C01246
C01251
Parameter | Name:
C01245 | MCK: Target detection - positions
Data type: INTEGER_32
Index: 23330
d
= 5B22
h
Position settings for various MCK functions
Setting range
(min. value | unit | max. value)
0.0000
units
214748.3647
Subcodes
Lenze setting
Info
C01245/1
1.0000 units
MCK: Window target position
• Window around the target position for comparison
with the actual position to see whether the drive is in
target.
C01245/2
1.0000 units
MCK: Blocking zone Modulo
•
From version 06.00.00
Activation of the Modulo measuring system
C01245/3
0.0000 units
MCKI: Hysteresis position change
•
From version 12.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01246 | MCK: Select signal source
Data type: UNSIGNED_8
Index: 23329
d
= 5B21
h
From version 06.00.00
Selection of the touch probe signal source for reference search with touch probe detection
• If the reference signal is to follow a real touch probe, the
must be configured accordingly.
Selection list
0 No TP
4 TP-DigIn4
5 TP-DigIn5
6 TP-DigIn6
Subcodes
Lenze setting
Info
C01246/1
0: No TP
MCK: Ref. TP signal source
C01246/2
0: No TP
MCK: Set.Ref. signal source
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01251 | MCK: Acceleration stop
Data type: INTEGER_32
Index: 23324
d
= 5B1C
h
Acceleration parameter for stop
Setting range
(min. value | unit | max. value)
-214748.3647
units/s2
214748.3647
Subcodes
Lenze setting
Info
C01251/1
720.0000 units/s2
MCK: Stop: Decel.
• Deceleration for setpoint speed ramp-down to
standstill.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000