7 monitoring, Monitoring, E monitoring – Lenze 8400 User Manual
Page 573: 9diagnostics & error management

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
573
9
Diagnostics & error management
9.7
Monitoring
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.7
Monitoring
The controller is provided with various monitoring functions which protect the drive against
impermissible operating conditions.
• If a monitoring function responds,
• an entry will be made into the
of the controller,
• the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will be
triggered,
• the status of the internal device control changes according to the selected response,
controller inhibit is set, and the "DRV- ERR" LED on the front of the controller goes on:
Related topics:
LED status displays of the device status
Device state machine and device statuses
Device overload monitoring (Ixt)
Motor temperature monitoring (PTC)
Brake resistor monitoring (I2xt)
Motor phase failure monitoring
Mains phase failure monitoring
Encoder open-circuit monitoring
Response
Entry in the
logbook
Display in
Pulse inhibit
Controller
inhibit
Acknowledge
ment
required
"DRV-ERR" LED
None
OFF
Fault
Trouble
TroubleQSP
WarningLocked
Warning
Information
OFF
System fault
Mains
switching
is required!