15 parameter reference, 3 table of attributes – Lenze E94AxPExxxx User Manual
Page 937

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
937
15
Parameter reference
15.3
Table of attributes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Motor voltage
Linear value
24523
5FCB
E
1
UNSIGNED_32
1
DC-bus voltage
Linear value
24522
5FCA
E
1
UNSIGNED_32
1
Motor current
Linear value
24521
5FC9
E
1
UNSIGNED_32
100
Phase currents
Linear value
24520
5FC8
A
4
INTEGER_32
100
Torque setpoint
Linear value
24519
5FC7
E
1
INTEGER_32
100
Torque
Linear value
24518
5FC6
A
2
UNSIGNED_32
1000
Pole position
Linear value
24517
5FC5
A
3
INTEGER_32
10
Motor - number of pole pairs
Linear value
24516
5FC4
E
1
UNSIGNED_32
1
Rotor position
Linear value
24515
5FC3
E
1
INTEGER_32
1
Heatsink temperature
Linear value
24514
5FC2
E
1
INTEGER_32
1
Interior temperature
Linear value
24513
5FC1
E
1
INTEGER_32
1
Motor temperature
Linear value
24512
5FC0
E
1
INTEGER_32
1
Device utilisation (Ixt)
Linear value
24511
5FBF
E
1
UNSIGNED_32
1
Ext. 24-V voltage
Linear value
24510
5FBE
E
1
INTEGER_32
10
Thermal motor load (I²xt)
Linear value
24509
5FBD
E
1
UNSIGNED_32
1
Capacitor temperature
Linear value
24507
5FBB
E
1
INTEGER_32
1
CPU temperature
Linear value
24506
5FBA
E
1
INTEGER_32
1
Speed controller gain
Linear value
24505
5FB9
E
1
UNSIGNED_32
100000
Speed controller reset time
Linear value
24504
5FB8
E
1
UNSIGNED_32
10
Speed controller rate time
Linear value
24503
5FB7
E
1
UNSIGNED_32
100
Feedfwd. ctrl. - current contr.
Selection list
24501
5FB5
E
1
UNSIGNED_8
1
Current controller gain
Linear value
24500
5FB4
E
1
UNSIGNED_32
100
Current contr. reset time
Linear value
24499
5FB3
E
1
UNSIGNED_32
100
Field controller gain
Linear value
24498
5FB2
E
1
UNSIGNED_32
100
Field contr. reset time
Linear value
24497
5FB1
E
1
UNSIGNED_32
10
Mutual motor inductance
Linear value
24496
5FB0
E
1
UNSIGNED_32
10
Number of resolver pole pairs
Linear value
24495
5FAF
E
1
UNSIGNED_32
1 CINH
Rated motor power
Linear value
24494
5FAE
E
1
UNSIGNED_32
100 CINH
Motor rotor resistance
Linear value
24493
5FAD
E
1
UNSIGNED_32
10000
Motor rotor time constant
Linear value
24492
5FAC
E
1
UNSIGNED_32
100
Motor stator resistance
Linear value
24491
5FAB
E
1
UNSIGNED_32
10000 CINH
Motor stator leakage inductance
Linear value
24490
5FAA
E
1
UNSIGNED_32
1000 CINH
Rated motor speed
Linear value
24488
5FA8
E
1
UNSIGNED_32
1 CINH
Rated motor current
Linear value
24487
5FA7
E
1
UNSIGNED_32
100 CINH
Rated motor frequency
Linear value
24486
5FA6
E
1
UNSIGNED_32
10 CINH
Rated motor voltage
Linear value
24485
5FA5
E
1
UNSIGNED_32
1 CINH
Motor cosine phi
Linear value
24484
5FA4
E
1
UNSIGNED_32
100 CINH
Motor magnetising current
Linear value
24483
5FA3
E
1
UNSIGNED_32
100
Field weakening for SM
Selection list
24482
5FA2
E
1
UNSIGNED_32
1
Firmware version
String
24476
5F9C
E
1
VISIBLE_STRING [12]
Resol. of an encoder revolution
Linear value
24475
5F9B
E
1
UNSIGNED_32
1 CINH
Decel. time - quick stop
Linear value
24470
5F96
E
1
UNSIGNED_32
1000
Quick stop S-ramp time
Linear value
24469
5F95
E
1
UNSIGNED_32
100
Ref. for quick stop dec. time
Selection list
24468
5F94
E
1
UNSIGNED_8
1
Digital input x - terminal pol.
Linear value
24461
5F8D
A
8
UNSIGNED_8
1
Digital output x - terminal pol.
Linear value
24457
5F89
A
4
UNSIGNED_8
1
Motor overload protection (I²xt)
Linear value
24455
5F87
E
1
UNSIGNED_32
1
Motor temp. warning threshold
Linear value
24454
5F86
E
1
UNSIGNED_32
1
Heatsink temp. warn. threshold
Linear value
24453
5F85
E
1
UNSIGNED_32
1
Device utilisation warning threshold
Linear value
24452
5F84
E
1
UNSIGNED_32
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)