0x008c0013, 0x008c0011, 0x008c000f – Lenze E94AxPExxxx User Manual
Page 706: 0x008c0012, 0x008c0010, 14 diagnostics & fault analysis

14
Diagnostics & fault analysis
14.7
Error messages of the operating system
706
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
MXI1: PROFIBUS module is missing or incompatible [0x008c000f]
MXI2: PROFIBUS module is missing or incompatible [0x008c0010]
MXI1: Ethernet module is missing or incompatible [0x008c0011]
MXI2: Ethernet module is missing or incompatible [0x008c0012]
MXI1: Digital frequency module is missing or incompatible [0x008c0013]
Module ID (decimal)
Error ID (decimal)
140: Application project manager
15
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
E94AYCPM communication module (PROFIBUS) in
module slot MXI1 is incompatible with the application.
Use communication module supported by the
application.
Module ID (decimal)
Error ID (decimal)
140: Application project manager
16
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
E94AYCPM communication module (PROFIBUS) in
module slot MXI2 is incompatible with the application.
Use communication module supported by the
application.
Module ID (decimal)
Error ID (decimal)
140: Application project manager
17
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
E94AYCEN communication module (Ethernet) in module
slot MXI1 is incompatible with the application.
Use communication module supported by the
application.
Module ID (decimal)
Error ID (decimal)
140: Application project manager
18
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
E94AYCEN communication module (Ethernet) in module
slot MXI2 is incompatible with the application.
Use communication module supported by the
application.
Module ID (decimal)
Error ID (decimal)
140: Application project manager
19
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Digital frequency extension module in module slot MXI1
is incompatible with the application.
Use extension module supported by the application.