_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.1
General information
6.1.1
Reading out motor data from the controller
If the Lenze motor connected to the controller has an electronic nameplate (ENP), the motor does
not need to be selected in the »Engineer« motor catalogue.
• With the first switch-on of the controller all motor data are automatically read out from the
electronic nameplate of the motor and at first are saved temporarily within the controller.
• For a permanent acceptance of the motor data, the parameter set must be saved (
= "11:
Save start parameters").
• If there is an online connection between »Engineer« and the controller, the motor data can be
accepted from the controller to the »Engineer« project.
How to read out the motor data from the controller:
1. Establish an online connection between »Engineer« and controller.
2. Select the Application parameters tab and change to the Overview Motor Motor dialog
level.
3. Click on the From Drive button.
• Then the motor data are read out of the controller and directly written into the
corresponding codes of the »Engineer« project.
Display parameters for electronic nameplate (ENP)
Parameter
Info
Lenze setting
Value Unit
ENP: Identified motor type
-
ENP: Identified serial number
-
ENP: Status
-