C02788 | poleposition setpoint, C02789 | polepositionidentification: dig. signals, C02800 | analog input x: input signal – Lenze E94AxPExxxx User Manual
Page 918: C02800/1, C02800/2, C02789/1, C02789/2, C02789/3, C02788, C02789/4
15
Parameter reference
15.2
Parameter list | C02788
918
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02788
C02789
C02800
Parameter | Name:
C02788 | PolePosition setpoint
Data type: INTEGER_32
Index: 21787
d
= 551B
h
From software version V2.0
Basic function "
Display range
(min. value | unit | max. value)
-214748364.8
°
214748364.7
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02789 | PolePositionIdentification: Dig. signals
Data type: UNSIGNED_32
Index: 21786
d
= 551A
h
From software version V2.0
Display of the digital signals of the basic function "
Selection list
(read only)
0 FALSE
1 TRUE
Subcodes
Info
C02789/1
PPI_bEnable
C02789/2
PPI_bStart
C02789/3
PPI_bLoadPolePosition
C02789/4
PPI_bResetPolePosition
C02789/5
PPI_bEnabled
C02789/6
PPI_bActive
C02789/7
PPI_bDone
C02789/8
PPI_bError
C02789/9
PPI_bPolePositionAvailable
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02800 | Analog input x: Input signal
Data type: INTEGER_16
Index: 21775
d
= 550F
h
Scaling: -16384 ≡ -100 %, +16383 ≡ +100 %
Display range
(min. value | unit | max. value)
-16384
16383
Subcodes
Info
C02800/1
Input signal - analog input 1
C02800/2
Analog input 2: Input signal
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1