15 parameter reference – Lenze E94AxPExxxx User Manual
Page 751

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
751
15
Parameter reference
15.2
Parameter list | C00003
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3342336 Device command executed successfully
51:
3342337 General error
3376386 Device command in process
3382023 Pole position identification cannot be executed because
of wrong motor type (asynchronous motor).
3382024 Pole position identification has been aborted
3382025 Pole position identification cannot be executed because
another identification is already active.
3382026 Identification of pole position cannot be executed
because U-rotation or I-rotation test mode is active.
3382027 Identification of pole position cannot be executed
because current controller optimisation mode is active.
3382033 Pole position identification cannot be executed because
the motor is blocked (e.g. by a mechanical brake), a
motor phase is not connected, or a phase shifter is in the
motor cable.
3382047 Pole position identification cannot be executed because
an error or trouble is active.
3382065 Pole position identification cannot be executed because
either the entire motor or a motor phase is not
connected.
3407872 Device command executed successfully
52:
3407873 General error
3441922 Device command in process
3447559 Pole position identification cannot be executed because
of wrong motor type (asynchronous motor).
3447560 Pole position identification has been aborted
3447561 Pole position identification cannot be executed because
another identification is already active.
3447562 Identification of pole position cannot be executed
because U-rotation or I-rotation test mode is active.
3447563 Identification of pole position cannot be executed
because current controller optimisation mode is active.
3447569 Pole position identification cannot be executed because
the motor is blocked (e.g. by a mechanical brake), a
motor phase is not connected, or a phase shifter is in the
motor cable.
3447583 Pole position identification cannot be executed because
an error or trouble is active.
3447597 Identification of pole position cannot be executed
because the rotor has moved too strongly.
3447601 Pole position identification cannot be executed because
either the entire motor or a motor phase is not
connected.
Status
Meaning
Device command