beautypg.com

C02526 | user-defined unit, C02527 | motor mounting direction, C02528 | traversing range – Lenze E94AxPExxxx User Manual

Page 874: C02529 | position encoder mounting dir, C02527, C02526, C02528, Aversing range, C02529, Position en

background image

15

Parameter reference

15.2

Parameter list | C02526

874

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02526

C02527

C02528

C02529

Parameter | Name:

C02526 | User-defined unit

Data type: VISIBLE_STRING

Index: 22049

d

= 5621

h

User-defined unit which is displayed when

C02525

="0" is selected.

Drive interface

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Character length: 8

Parameter | Name:

C02527 | Motor mounting direction

Data type: UNSIGNED_32

Index: 22048

d

= 5620

h

Drive interface

Selection list

(Lenze setting printed in bold)

0 Motor rotating CW
1 Motor rotating CCW

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02528 | Traversing range

Data type: UNSIGNED_32

Index: 22047

d

= 561F

h

Drive interface

Selection list

(Lenze setting printed in bold)

0 Unlimited
1 Limited
2 Modulo

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02529 | Position encoder mounting dir.

Data type: UNSIGNED_32

Index: 22046

d

= 561E

h

Drive interface

Selection list

(Lenze setting printed in bold)

0 Encoder rotating CW
1 Encoder rotating CCW

Read access  Write access  CINH  PLC STOP  No transfer