C00776 | mctrl_dninputjerkctrl, C00777 | mctrl_dninputtorquectrl, C00778 | mctrl_dnfluxact – Lenze E94AxPExxxx User Manual
Page 838: C00779 | mctrl_dndcbusvoltage, C00780 | mctrl_dnimotact, C00780, 15 parameter reference
15
Parameter reference
15.2
Parameter list | C00776
838
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00776
C00777
C00778
C00779
C00780
Parameter | Name:
C00776 | MCTRL_dnInputJerkCtrl
Data type: INTEGER_32
Index: 23799
d
= 5CF7
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-21474836.47
Nm
21474836.47
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00777 | MCTRL_dnInputTorqueCtrl
Data type: INTEGER_32
Index: 23798
d
= 5CF6
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-21474836.47
Nm
21474836.47
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00778 | MCTRL_dnFluxAct
Data type: INTEGER_32
Index: 23797
d
= 5CF5
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00779 | MCTRL_dnDCBusVoltage
Data type: INTEGER_32
Index: 23796
d
= 5CF4
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0
V
1000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00780 | MCTRL_dnImotAct
Data type: INTEGER_32
Index: 23795
d
= 5CF3
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-500.00
A
500.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100