Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
543
12
Basic drive functions
12.11
Limiter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
• If the drive is already outside the permissible travel range and the software limit positions have
been activated, only travel commands that result in the drive moving back into the permissible
travel range can be executed:
[12-27] Example: Permissible traversing direction if software limit positions active
• If the software limit positions are active and a software limit position is passed ("overtravel"):
• The error response "quick stop by trouble" is carried out in the Lenze setting, i.e. the drive is
braked to standstill within the deceleration time set for the quick stop function irrespective
of the setpoint selection. The error response can be parameterised in
• The fault message "Pos. SW limit switch overtravelled" or "Neg. SW limit overtravelled" is
entered in the logbook of the controller.
• A corresponding status is output via the LIM_dnState output.
• Depending on the parameterised fault response, the drive cannot traverse until the error has
been acknowledged.
See also:
: Negative software limit position
: Positive software limit position
Traversing in "retracting direction" possible
Traversing opposite to "retracting direction" not possible
C02701/2
C02701/1
ü
1
0
dnState
Bit 4