C02581
C02582
C02583
C02585
C02586
Parameter | Name:
C02581 | Threshold - brake activation
Data type: INTEGER_32
Index: 21994
d
= 55EA
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0
rpm
50000 50 rpm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02582 | Brake resp. to pulse inhibit
Data type: UNSIGNED_32
Index: 21993
d
= 55E9
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Activate the brake immediately
1 Activate brake when n < nmin
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02583 | Status input monitoring
Data type: UNSIGNED_32
Index: 21992
d
= 55E8
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Not active
1 Active
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02585 | Brake control polarity
Data type: UNSIGNED_32
Index: 21990
d
= 55E6
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Not inverted
1 Inverted
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02586 | Starting torque 1
Data type: INTEGER_32
Index: 21989
d
= 55E5
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
-21474836.47
Nm
21474836.47 0.00 Nm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100