C00641
C00642
C00643
C00644
Parameter | Name:
C00641 | PLI 360° current amplitude
Data type: UNSIGNED_32
Index: 23934
d
= 5D7E
h
Percentage adjustment of the current amplitude for the
Stop!
If there is no temperature monitoring in the motor and/or the I2xt motor monitoring is not parameterised correctly,
the motor may be permanently damaged when the current amplitude is set too high (e.g. to the maximum value)!
Adjustment of the pole position identification
Setting range
(min. value | unit | max. value)
Lenze setting
1
%
1000 100 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00642 | PolePosId 360° ramp time
Data type: UNSIGNED_32
Index: 23933
d
= 5D7D
h
Percentage adjustment of the ramp time for the
Adjustment of the pole position identification
Setting range
(min. value | unit | max. value)
Lenze setting
5
%
1000 100 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00643 | PLI 360° traversing direction
Data type: UNSIGNED_32
Index: 23932
d
= 5D7C
h
Selection of the traversing direction for the
Adjustment of the pole position identification
Selection list
(Lenze setting printed in bold)
0 Right rotating field
1 Left rotating field
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00644 | PolePosId 360° fault tol.
Data type: INTEGER_32
Index: 23931
d
= 5D7B
h
Fault tolerance for the plausibility check of the
Adjustment of the pole position identification
Setting range
(min. value | unit | max. value)
Lenze setting
-6.0
°
30.0 0.0 °
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10