beautypg.com

C00969 | vfc: limitation - oscill. damp, C00970 | vfc: ramp-end frequ. - oscill. damp, C00971 | vfc: influence - speed controller – Lenze E94AxPExxxx User Manual

Page 850: C00972 | vfc: gain - speed controller, C00973 | vfc: reset time - speed contr, C00969, C00970, Defi, C00971, C00972

background image

15

Parameter reference

15.2

Parameter list | C00969

850

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00969

C00970

C00971

C00972

C00973

Parameter | Name:

C00969 | VFC: Limitation - oscill. damp.

Data type: INTEGER_32

Index: 23606

d

= 5C36

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0.1

Hz

20.0 0.2 Hz

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00970 | VFC: ramp-end frequ. - oscill. damp.

Data type: INTEGER_32

Index: 23605

d

= 5C35

h

From software version V2.0

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 0 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00971 | VFC: Influence - speed controller

Data type: UNSIGNED_32

Index: 23604

d

= 5C34

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 10.00 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00972 | VFC: Gain - speed controller

Data type: UNSIGNED_32

Index: 23603

d

= 5C33

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

Hz/rpm

1000.000 0.000 Hz/rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C00973 | VFC: Reset time - speed contr.

Data type: UNSIGNED_32

Index: 23602

d

= 5C32

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 6000.0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10