Homing mode not allowed [0x00b80019, Ta" (error number, 0x00b80034 – Lenze E94AxPExxxx User Manual
Page 736: 0x00b80016, 0x00b80017, 0x00b80019, 14 diagnostics & fault analysis
14
Diagnostics & fault analysis
14.7
Error messages of the operating system
736
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Cam data locked due to incorrect password [0x00b80016]
Cam data locked due to incorrect safety key [0x00b80017]
Homing mode not allowed [0x00b80019]
Cam data: Invalidated due to change of mechanical data [0x00b80034]
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
22
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The cam data were locked since the user password was
entered incorrectly for three times.
The cam data were not loaded.
Reset parameters to the Lenze setting via device
command
= "0: Load Lenze setting". Then
download cam data again.
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
23
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The cam data were not loaded because the safety key is
damaged.
The password in the cam data or the serial number of the
memory module has been manipulated.
Reset parameters to the Lenze setting via device
command
= "0: Load Lenze setting". Then
download cam data again.
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
25
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The homing mode selected in
is not supported in
the motor control type selected in
Select another homing mode in
.
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
52
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
One or several machine parameters which have an
influence on the internal scaling of the cam data have
been changed. The cam data have to be recalculated.
Execute device command