4 dc-injection braking, Dc-injection braking, Dc-injection braking ( 260) – Lenze E94AxPExxxx User Manual
Page 260: 6motor interface

6
Motor interface
6.8
Parameterisable additional functions
260
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.8.4
DC-injection braking
DC-injection braking can be divided into three functionalities:
Manual DC-injection braking
Braking can be activated and deactivated via the internal interface QSP_bActivateDCBrake of the
basic function "
".
Tip!
A detailed description of this functionality can be found in the main chapter "Basic drive
functions", subchapter "
DC-injection braking instead of quick stop
If DC-injection braking is activated in
instead of quick stop, DC-injection braking is executed
automatically when quick stop is activated.
Tip!
A detailed description of this functionality can be found in the main chapter "Basic drive
functions", subchapter "
DC-injection braking when quick stop is activated
Automatic DC-injection braking
This functionality is part of the basic function "
".
If mode 22 has been selected for the brake control in
, DC-injection braking is executed
automatically if the current speed setpoint falls below the speed threshold set in
Tip!
A detailed description of this functionality can be found in the main chapter "Basic drive
functions", subchapter "
":
Mode 22: Automatic DC-injection braking
Note!
Function only possible for V/f control or sensorless vector control!