beautypg.com

C02674 | pos_dwactualprofilenumber, C02675 | pos_dnstate, C02676 | pos_dnprofilespeed_s – Lenze E94AxPExxxx User Manual

Page 902: C02677 | positioning: % signals, C02677/1, C02677/2, C02677/3, C02675, C02676, C02674

background image

15

Parameter reference

15.2

Parameter list | C02674

902

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02674

C02675

C02676

C02677

Parameter | Name:

C02674 | POS_dwActualProfileNumber

Data type: UNSIGNED_32

Index: 21901

d

= 558D

h

Current profile of the basic function "

Positioning

".

Display range

(min. value | unit | max. value)

0

1000

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02675 | POS_dnState

Data type: INTEGER_32

Index: 21900

d

= 558C

h

Bit coded status of the basic function "

Positioning

".

Display range

(min. value | unit | max. value)

-2147483648

2147483647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02676 | POS_dnProfileSpeed_s

Data type: INTEGER_32

Index: 21899

d

= 558B

h

Display of the max. speed of the current profile of the basic function "

Positioning

".

Display range

(min. value | unit | max. value)

-214748.3647

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02677 | Positioning: % signals

Data type: INTEGER_32

Index: 21898

d

= 558A

h

Display of the scaled signals of the basic function "

Positioning

".

Display range

(min. value | unit | max. value)

-200.00

%

200.00

Subcodes

Info

C02677/1

POS_dnSpeedOverride_n

C02677/2

POS_dnAccOverride_n

C02677/3

POS_dnDecOverride_n

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100