5 sensorless vector control (slvc), Sensorless vector control (slvc), Sensorless vector control (slvc) ( 211) – Lenze E94AxPExxxx User Manual
Page 211: 6motor interface

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
211
6
Motor interface
6.5
Sensorless vector control (SLVC)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.5
Sensorless vector control (SLVC)
If this motor control mode is set in
, a considerably higher torque and a lower current
consumption in idle state can be achieved compared to the V/f control mode.
Tip!
For vertical drives/hoists, use the servo control (with feedback), or the V/f control with
activated voltage vector control (VVC), which supports vertical drives/hoists up to 55 kW.
Note!
Observe the following application limits of the sensorless vector control:
• Only approved for power up to 55 kW and horizontal applications (no hoists or lifting
equipment)
• For single drives only
• For asynchronous motors only
• Not suitable for operation in generator mode/braking operation (e. g. unwinders)