C00792 | mctrl_dnoutputposctrlmotor_s, C00800 | mctrl_dnposset, C00802 | mctrl_dnspeedadd – Lenze E94AxPExxxx User Manual
Page 841: C00803 | mctrl_dntorqueadd, C00804 | mctrl_dnaccelerationadd, 15 parameter reference

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
841
15
Parameter reference
15.2
Parameter list | C00792
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00792
C00800
C00802
C00803
C00804
Parameter | Name:
C00792 | MCTRL_dnOutputPosCtrlMotor_s
Data type: INTEGER_32
Index: 23783
d
= 5CE7
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200
%
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00800 | MCTRL_dnPosSet
Data type: UNSIGNED_32
Index: 23775
d
= 5CDF
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0
Incr.
4294967295
Subcodes
Info
C00800/1
LOW word
C00800/2
High word
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00802 | MCTRL_dnSpeedAdd
Data type: INTEGER_32
Index: 23773
d
= 5CDD
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-480000
rpm
480000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00803 | MCTRL_dnTorqueAdd
Data type: INTEGER_32
Index: 23772
d
= 5CDC
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-2147483.647
Nm
2147483.647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C00804 | MCTRL_dnAccelerationAdd
Data type: INTEGER_32
Index: 23771
d
= 5CDB
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-2147483.647
1/s²
2147483.647
Read access Write access CINH PLC STOP No transfer