_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02598
C02599
C02600
C02601
C02602
Parameter | Name:
C02598 | Grinding ON time
Data type: UNSIGNED_32
Index: 21977
d
= 55D9
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.2
s
2.0 0.5 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02599 | Grinding OFF time
Data type: UNSIGNED_32
Index: 21976
d
= 55D8
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.2
s
2.0 0.5 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02600 | Acceleration time feedf. control
Data type: UNSIGNED_32
Index: 21975
d
= 55D7
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
1000.000 0.000 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02601 | Ref. for Accel. time of brake
Data type: UNSIGNED_32
Index: 21974
d
= 55D6
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Motor reference value
1 Current starting value
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02602 | Source for feedf. control brake
Data type: UNSIGNED_32
Index: 21973
d
= 55D5
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Torque
1 Speed
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1