C00805 | mctrl_dnspeedlowlimit, C00806 | mctrl_dntorquelowlimit, C00807 | mctrl_dntorquehighlimit – Lenze E94AxPExxxx User Manual
Page 842: C00808 | mctrl_dnposctrloutlimit, C00809 | mctrl_dntorquectrladapt, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00805
842
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00805
C00806
C00807
C00808
C00809
Parameter | Name:
C00805 | MCTRL_dnSpeedLowLimit
Data type: INTEGER_32
Index: 23770
d
= 5CDA
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-480000
rpm
480000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00806 | MCTRL_dnTorqueLowLimit
Data type: INTEGER_32
Index: 23769
d
= 5CD9
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-21474836.47
Nm
21474836.47
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00807 | MCTRL_dnTorqueHighLimit
Data type: INTEGER_32
Index: 23768
d
= 5CD8
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-21474836.47
Nm
21474836.47
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00808 | MCTRL_dnPosCtrlOutLimit
Data type: INTEGER_32
Index: 23767
d
= 5CD7
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-480000
rpm
480000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00809 | MCTRL_dnTorqueCtrlAdapt
Data type: INTEGER_32
Index: 23766
d
= 5CD6
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100