12 basic drive functions – Lenze E94AxPExxxx User Manual
Page 456

12
Basic drive functions
12.6
Homing
456
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Note!
For homing, setpoint speeds greater than 30000 rpm are not possible. The speeds
defined for these basic function are internally limited to 30000 rpm.
When the basic function is activated, a start acceleration is considered.
acceleration/acceleration reduction when the basic function changes
The following applies to the encoderless motor control types :
If the V/f control or sensorless vector control is selected, the basic function "Homing" can
be activated, irrespective of the use of the position controller.
• If no position controller has been selected for the position control in case of V/f
control or sensorless vector control (
= "1: Phase controller is active"), homing
is only carried out via the speed profile resulting from the homing parameters.
Because of this, the target positions set will only "roughly" be reached.