Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

763

15

Parameter reference

15.2

Parameter list | C00065

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00065

C00066

C00068

C00069

C00070

C00071

Parameter | Name:

C00065 | Ext. 24-V voltage

Data type: INTEGER_32

Index: 24510

d

= 5FBE

h

Display range

(min. value | unit | max. value)

0.0

V

1000.0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00066 | Thermal motor load (I²xt)

Data type: UNSIGNED_32

Index: 24509

d

= 5FBD

h

A 100 % load corresponds to a permanently flowing rated motor current

I2xt motor monitoring

Display range

(min. value | unit | max. value)

0

%

250

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00068 | Capacitor temperature

Data type: INTEGER_32

Index: 24507

d

= 5FBB

h

Display range

(min. value | unit | max. value)

-200

°C

200

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00069 | CPU temperature

Data type: INTEGER_32

Index: 24506

d

= 5FBA

h

Display range

(min. value | unit | max. value)

-200

°C

200

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00070 | Speed controller gain

Data type: UNSIGNED_32

Index: 24505

d

= 5FB9

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00000

Nm/rpm

20000.00000 0.00044 Nm/rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100000

Parameter | Name:

C00071 | Speed contr. reset time

Data type: UNSIGNED_32

Index: 24504

d

= 5FB8

h

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 14.4 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10