6motor interface – Lenze E94AxPExxxx User Manual
Page 166

6
Motor interface
6.1
General information
166
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.1.2
Selecting a motor from the motor catalogue in the »Engineer«
If the Lenze motor does not have an electronic nameplate (ENP) or if a motor of a third-party
manufacturer is used, select the motor in »Engineer« via the motor catalogue and transfer the
motor data to the controller.
• If a checkmark is set in the Motor control field in the "Other components" dialog when the
controller is inserted into the project, the motor for the controller can be selected from the
motor catalogue in another dialog:
• Alternatively, the motor can be inserted into the project at a later time via the Insert a
component command.
Tip!
If a third party manufacturer's motor is used, select a Lenze motor from the motor
catalogue first which is similar in terms of current, voltage and speed rating. Adapt the
preselected motor data exactly to the real motor afterwards.
Displaying/editing motor data in »Engineer«