I-1802/1, I-1803/1, I-1803 – Lenze E94AxPExxxx User Manual
Page 401: 10 "can on board" system bus
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
401
10
"CAN on board" system bus
10.10
Implemented CANopen objects | I-1802
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
I-1802
Communication parameter for sending process data via TPDO3
• For assignment of the data telegram see object
I-1803
Communication parameter for the transmission of process data via TPDO4
• For assignment of the data telegram see object
Index:
I-1802
Name:
TPDO3 communication parameter
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: Highest subindex supported
5
- (read access only)
ro
U8
1: COB-ID used by TPDO
0x380 + node ID
0
4294967295 rw
U32
2: Transmission type
254
0
255 rw
U8
3: Inhibit time
0 ms
0
0.1 ms
65535 rw
U16
4: Reserved
-
- (reserved, read or write access leads to error message
0x06090011)
rw
U8
5: Event timer
0 ms
0
ms
65535 rw
U16
Subindex
Meaning
Lenze code
1
TPDO3 identifier
• The basic setting is according to the "Predefined
Connection Set": Identifier = 0x380 + node ID
2
TPDO transmission type according to DS301 V4.02
3
Minimum time between sending two identical TPDOs
(see DS301 V4.02).
5
Cycle time for PDO transmission with transmission type
"254".
Index:
I-1803
Name:
TPDO4 communication parameter
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: Highest subindex supported
5
- (read access only)
ro
U8
1: COB-ID used by TPDO
0x480 + node ID
0
4294967295 rw
U32
2: Transmission type
254
0
255 rw
U8
3: Inhibit time
0 ms
0
0.1 ms
65535 rw
U16
4: Reserved
-
- (reserved, read or write access leads to error message
0x06090011)
rw
U8
5: Event timer
0 ms
0
ms
65535 rw
U16
Subindex
Meaning
Lenze code
1
Identifier TPDO4
• The basic setting is according to the "Predefined
Connection Set": Identifier = 0x480 + node ID
2
TPDO transmission type according to DS301 V4.02
3
Minimum time between sending two identical TPDOs
(see DS301 V4.02).
5
Cycle time for PDO transmission with transmission type
"254".