12.13.3.2 Online change mode
During running operation, new cam data can be downloaded from »Engineer« to the controller if
the controller is in storage mode 1 or 2.
• If the cam data are provided with an access protection, the user password has to be entered first.
• The time when the new/altered cam data are accepted depends on the online change mode set
in
.
Mode 16: Automatic activation with CINH
In the Lenze setting, the online change mode "Automatic activation with CINH" is set in
, i.e.
the new cam data are accepted automatically as soon as the controller is inhibited.
[12-49] Online change mode "Automatic activation with CINH"
Note!
If the controller is in storage mode 3, the "Online change" function is deactivated:
• The online change mode set in
is ineffective.
• In
the status "999: Online change deactivated" is displayed.
• For the download of new cam data, controller inhibit is required.
• The cam data are accepted immediately after download.