3 displaying/editing motor data in »engineer, Displaying/editing motor data in »engineer, 6motor interface – Lenze E94AxPExxxx User Manual
Page 167
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
167
6
Motor interface
6.1
General information
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.1.3
Displaying/editing motor data in »Engineer«
The term "Motor data" combines all parameters that only depend on the motor. They solely
characterise the electrical behaviour of the machine.
• The motor data do not depend on the application in which the controller and motor are used.
• The motor data are, if available in »Engineer« via electronic nameplate or motor catalogue,
accepted by the controller without confirmation prompt.
In »Engineer« the motor data are shown on the Application parameters tab in the dialog level
OverviewMotorMotor:
• If you use a motor of a third-party manufacturer, the displayed motor data can be adapted
exactly to the existing motor by clicking the From Project button and then selecting the "Own
motor settings" entry in the Motor selection dialog box.
• Via the From Motor Catalogue button, the motor catalogue can be opened to select another
Selecting a motor from the motor catalogue in the »Engineer«
• If an online connection has been established, the motor data set in the controller can be
accepted in »Engineer« via the button From Drive.
Reading out motor data from the controller