C00055 | phase currents, C00056 | torque setpoint, C00057 | torque – Lenze E94AxPExxxx User Manual
Page 761: C00058 | pole position, C00058, C00057/1, C00057/2, C00058/1, Ge in, C00058/2

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
761
15
Parameter reference
15.2
Parameter list | C00055
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00055
C00056
C00057
C00058
Parameter | Name:
C00055 | Phase currents
Data type: INTEGER_32
Index: 24520
d
= 5FC8
h
Display range
(min. value | unit | max. value)
-500.00
A
500.00
Subcodes
Info
C00055/1
Phase zero system
C00055/2
Phase U
C00055/3
Phase V
C00055/4
Phase W
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00056 | Torque setpoint
Data type: INTEGER_32
Index: 24519
d
= 5FC7
h
Display range
(min. value | unit | max. value)
-21474836.47
Nm
21474836.47
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00057 | Torque
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Display range
(min. value | unit | max. value)
0.000
Nm
2147483.647
Subcodes
Info
C00057/1
Maximum torque
• With regard to the selected motor and the max. short-
time output current of the device.
C00057/2
Motor reference torque
• Torque at maximum current (
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C00058 | Pole position
Data type: INTEGER_32
Index: 24517
d
= 5FC5
h
Setting range
(min. value | unit | max. value)
-179.9
°
179.9
Subcodes
Lenze setting
Info
C00058/1
-90.0 °
Resolver pole position
C00058/2
0.0 °
Encoder pole position
C00058/3
0.0 °
Module pole position
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10