C00128 | therm. motor time constant, C00129 | brake resistance value, C00130 | rated power - brake resistor – Lenze E94AxPExxxx User Manual
Page 770: C00131 - rated quantity of heat for brake res, C00128/1, C00128/2, C00129, C00130, C00131, Meterised in

15
Parameter reference
15.2
Parameter list | C00128
770
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00128
C00129
C00130
C00131
C00132
Parameter | Name:
C00128 | Therm. motor time constant
Data type: UNSIGNED_32
Index: 24447
d
= 5F7F
h
Setting range
(min. value | unit | max. value)
0.1
min
600.0
Subcodes
Lenze setting
Info
C00128/1
1.0 min
Therm. time constant coil
C00128/2
5.0 min
Therm. time constant plates
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00129 | Brake resistance value
Data type: INTEGER_32
Index: 24446
d
= 5F7E
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
Ohm
500.0 180.0 Ohm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00130 | Rated power - brake resistor
Data type: INTEGER_32
Index: 24445
d
= 5F7D
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value)
Lenze setting
0
W
800000 5600 W
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00131 - Rated quantity of heat for brake res.
Data type: INTEGER_32
Index: 24444
d
= 5F7C
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value)
Lenze setting
0
kWs
100000 485 kWs
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00132 | Service code
Data type: INTEGER_32
Index: 24443
d
= 5F7B
h
This code is for device-internal use only and must not be written to by the user!