Memory modules
In order to use the PLC functionality, the memory module MM340 or MM440 (licence: "PLC") must
be plugged in the controller. Saving with mains failure protection of the IEC61131-3 program into
another memory module is not possible.
The following table compares the storage capacities and functions of both memory modules:
4.8.7
Known function restrictions of the controller
Restrictions when working with the SysLibTime.lib library
The structure entry DayOfWeek of the function block CurTimeEx is not supported by the controller.
Device error by aborting a trace recording
A started trace recording must be stopped with the command "Stop trace".
Otherwise, a device error occurs in case of a premature log-out that can only be reset by mains
switching of the controller.
Project options in »PLC Designer«
In the PLC project under the menu item ProjectOptionsSource download, the setting "Only on
request" must be activated at the time of download. Otherwise, an error message will be generated
when a boot project is created.
MM340
MM440
Size of the file system
• For example for »Engineer« project data, programs, and
parameter sets.
4 MByte
8 MByte
4992 Byte
64 kByte
CAN address switch
• For system bus "CAN on board".
Real-time clock
• For adjusting the system time at switch-on.
• Display in
.