4 "ls_touchprobemotor" system block, 5 "ls_touchprobeload" system block, Ls_touchprobemotor" system block – Lenze E94AxPExxxx User Manual
Page 331: Ls_touchprobeload" system block, Touch-probe-motor, Touch-probe-load, Ls_touchprobemotor, Ls_touchprobeload, 9i/o terminals

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
331
9
I/O terminals
9.7
Touch probe detection
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.7.4
"LS_TouchProbeMotor" system block
9.7.5
"LS_TouchProbeLoad" system block
Output
Data type
Value/meaning
TPM_dnTouchProbeTimeLag
DINT
Scaled time stamp for further processing of the touch probe event with the
L_SdTouchProbe FB.
TPM_bTouchProbeReceived
BOOL
Status signal "Touch probe detected"
• State is only set for one task cycle.
TRUE Touch probe event has been activated.
TPM_bTouchProbeLost
BOOL
Status signal "Touch probe(s) lost"
• State is only set for one task cycle.
TRUE More than one touch probe event was actuated within the task
runtime and therefore could not be detected anymore.
TPM_dnTouchProbeTimeLag
TPM_bTouchProbeReceived
TPM_bTouchProbeLost
LS_TouchProbeMotor
TP
Output
Data type
Value/meaning
TPL_dnTouchProbeTimeLag
DINT
Scaled time stamp for further processing of the touch probe event with the
L_SdTouchProbe FB.
TPL_bTouchProbeReceived
BOOL
Status signal "Touch probe detected"
• State is only set for one task cycle.
TRUE Touch probe event has been activated.
TPL_bTouchProbeLost
BOOL
Status signal "Touch probe(s) lost"
• State is only set for one task cycle.
TRUE More than one touch probe event was actuated within the task
runtime and therefore could not be detected anymore.
TPL_dnTouchProbeTimeLag
TPL_bTouchProbeReceived
TPL_bTouchProbeLost
LS_TouchProbeLoad
TP