Parameter reference
15.2
Parameter list | C01502
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01502
C01510
C01511
Parameter | Name:
C01502 | Resp. to comm. error with MXI2
Data type: UNSIGNED_32
Index: 23073
d
= 5A21
h
Response to communication error between "intelligent" module in module slot 2 and standard device
Selection list
(Lenze setting printed in bold)
0 No response
1 Fault
3 Quick stop by trouble
4 Warning locked
5 Warning
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01510 | Ethernet IP address client x
Data type: VISIBLE_STRING
Index: 23065
d
= 5A19
h
Display of the three possible server channels
• If a client is connected via one of these server channels, the IP address and the port of the client will be indicated
in the form of "xxx.xxx.xxx.xxx : yyyy".
• If no client is connected via the server channel, "---.---.---.--- : ----" will be indicated.
Subcodes
Info
C01510/1
Server channel 1 ... 3
C01510/...
C01510/3
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Character length: 24
Parameter | Name:
C01511 | Ethernet status client x
Data type: UNSIGNED_8
Index: 23064
d
= 5A18
h
Status of the three possible server channels
Selection list
(read only)
0 Not connected
1 Connected
2 Stop
3 Unknown status
Subcodes
Info
C01511/1
State of server channels 1 ... 3
C01511/...
C01511/3
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1