C00959
C00960
C00961
C00962
C00963
Parameter | Name:
C00959 | VFC: VVC reset time
Data type: UNSIGNED_32
Index: 23616
d
= 5C40
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
ms
2000.00 2000.00 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00960 | VFC: V/f voltage boost
Data type: INTEGER_32
Index: 23615
d
= 5C3F
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
V
1000 0 V
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00961 | VFC: Load - cw/ccw-operation
Data type: UNSIGNED_32
Index: 23614
d
= 5C3E
h
Selection list
(Lenze setting printed in bold)
0 CW: mot. / CCW: mot.
1 CW: mot. / CCW: regen.
2 CW: regen. / CCW: mot.
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00962 | VFC: Load adjustment
Data type: UNSIGNED_32
Index: 23613
d
= 5C3D
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
200.00 20.00 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00963 | VFC: Gain - Imax controller
Data type: UNSIGNED_32
Index: 23612
d
= 5C3C
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
Hz/A
1000.000 0.001 Hz/A
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000