1 password entry, 12 basic drive functions – Lenze E94AxPExxxx User Manual
Page 593

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
593
12
Basic drive functions
12.13
Cam data management
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.13.3.1 Password entry
If a password has been defined for the cam data in »Engineer«, the defined user password must be
entered once to execute the following actions:
• Download of new cam data during operation
Entry of the existing password in »Engineer«.
• Change of the cam data via parameter setting
Entry of the existing password in
.
• Loading/saving of the cam data
entry of the existing password in
Tip!
The access protection for the cam data can be configured on the Online tab.
Validity
The user password entered in
is maintained until the next download, mains switching, or
until reset by the user (logout).
• You can "log out" deliberately by entering an invalid password into
Behaviour in case of invalid entry
If the user password is entered incorrectly three times, the cam data are blocked. A correct entry
resets the number of the failed attempts.
To remove the blocking of the cam data, there are two possibilities:
A. Resetting the parameters to the Lenze setting via device command
= "0: Load Lenze
setting".
• When the Lenze setting is loaded, the cam data are deleted.
• Afterwards the cam data can be transferred to the device again.
B. Transfer complete application to the device again.
• The application available and the cam data are deleted and all data are transferred to the
device again.
Note!
For saving the cam data, you do not need to enter a possibly existing user password
anymore.