C00645 | pli 360˚ absolute current amplitude, C00646 | pli min.mov. curr. amplitude, C00647 | poleposid min.mov. cur.rise rate – Lenze E94AxPExxxx User Manual
Page 833: C00648 | poleposid min.mov. gain, C00649 | pli min. mov. reset time, C00646, C00648, C00649, C00647, 15 parameter reference

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
833
15
Parameter reference
15.2
Parameter list | C00645
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00645
C00646
C00647
C00648
C00649
Parameter | Name:
C00645 | PLI 360° absolute current amplitude
Data type: UNSIGNED_32
Index: 23930
d
= 5D7A
h
From software version V2.0
Adjustment of the pole position identification
Display range
(min. value | unit | max. value)
0.00
A
1000.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00646 | PLI min.mov. curr. amplitude
Data type: UNSIGNED_32
Index: 23929
d
= 5D79
h
Percentage adjustment of the current amplitude for the
Stop!
If there is no temperature monitoring in the motor and/or the I2xt motor monitoring is not parameterised correctly,
the motor may be permanently damaged when the current amplitude is set too high (e.g. to the maximum value)!
Adjustment of the pole position identification
Setting range
(min. value | unit | max. value)
Lenze setting
1
%
1000 100 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00647 | PolePosId min.mov. cur.rise rate
Data type: UNSIGNED_32
Index: 23928
d
= 5D78
h
Percentage adjustment of the rate of current rise for the
Adjustment of the pole position identification
Setting range
(min. value | unit | max. value)
Lenze setting
5
%
1000 100 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00648 | PolePosId min.mov. gain
Data type: UNSIGNED_32
Index: 23927
d
= 5D77
h
P component of the PI controller for the
Adjustment of the pole position identification
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
10.00 0.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00649 | PLI min. mov. reset time
Data type: UNSIGNED_32
Index: 23926
d
= 5D76
h
I component of the PI controller for the
Adjustment of the pole position identification
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
ms
6000.00 62.50 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100