4plc functionality – Lenze E94AxPExxxx User Manual
Page 58

4
PLC functionality
4.5
Use of system blocks
58
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Overview of system blocks
The following table lists the system blocks that you can enter into »PLC Designer« in the control
configuration.
Module number
Designation in »PLC Designer«
Description
Device interfaces
100, 101, 104, 105
CAN_onBoard
System bus interface "CAN on board"
200, 201, 600 ... 604
EXTENSION_BOARDS_SLOT1
Interface MXI1 for fieldbus modules
300, 301, 600 ... 604
EXTENSION_BOARDS_SLOT2
Interface MXI2 for fieldbus modules
11 ... 13
ANALOG_IO
1 ... 3
DIGITAL_IO
139 ... 150
TP_TouchProbe
102 ... 103
SYNC_Synchronisation
404 ... 405
SMI_SafetyModuleInterface
Interface to the safety module
Drive and motor interface
152 ... 154
DI_DriveInterface
155 ... 157
MI_MotorInterface
Basic drive functions
158 ... 160
BRK_Brake
161 ... 163
FDB_Feedback
164 ... 166
HM_Homing
167 ... 169
LIM_Limiter
170 ... 172
MAN_ManualJog
173 ... 175
POS_Positioner
176 ... 178
PF_PositionFollower
179 ... 181
QSP_Quickstop
182 ... 184
SF_SpeedFollower
185 ... 186
STP_Stop
187 ... 189
TF_TorqueFollower
193 ... 195
CAM_CamInterface
196, 197
SSI_Encoder
198, 199, 500
MOL_ManualJogOpenLoop
501 ... 503
PPI_PolePositionIdentification
504, 505
ENC_EncoderX8