C00594 | resp. temp. sensor motor x7/x8, C00595 | resp. to can bus off, C00596 | threshold max. speed reached – Lenze E94AxPExxxx User Manual
Page 824: C00596, And select the error response, C00594, C00595, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00594
824
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00594
C00595
C00596
Parameter | Name:
C00594 | Resp. temp. sensor motor X7/X8
Data type: UNSIGNED_32
Index: 23981
d
= 5DAD
h
Response to motor temperature sensor error.
• The response to a too high motor temperature via PTC input T1/T2 can be selected in
.
Selection list
(Lenze setting printed in bold)
1 Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00595 | Resp. to CAN bus OFF
Data type: UNSIGNED_8
Index: 23980
d
= 5DAC
h
Response if CAN node switches to the bus off state.
Selection list
(Lenze setting printed in bold)
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00596 | Threshold max. speed reached
Data type: UNSIGNED_32
Index: 23979
d
= 5DAB
h
Threshold for speed monitoring
• The response to reaching the threshold can be selected in
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
50000 6500 rpm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1