C02944 | cont pos x0, C02945 | cont pos x1, C02946 | cont time – Lenze E94AxPExxxx User Manual
Page 933: C02959 | number of pos tracks, C02960 | pos track choice, C02944, C02945, C02946, C02959, C02960

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
933
15
Parameter reference
15.2
Parameter list | C02944
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02944
C02945
C02946
C02959
C02960
Parameter | Name:
C02944 | Cont Pos X0
Data type: INTEGER_32
Index: 21631
d
= 547F
h
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
-214748.3647
Unit
214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02945 | Cont Pos X1
Data type: INTEGER_32
Index: 21630
d
= 547E
h
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
-214748.3647
Unit
214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02946 | Cont Time
Data type: UNSIGNED_32
Index: 21629
d
= 547D
h
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
0.0000
ms
214748.3647 0.0000 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02959 | Number of Pos Tracks
Data type: UNSIGNED_32
Index: 21616
d
= 5470
h
Changing cam data via parameterisation
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02960 | Pos Track Choice
Data type: UNSIGNED_32
Index: 21615
d
= 546F
h
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1