Control card is defect (vcc5) [0x00780009, Device command transferred incorrectly [0x00790000, Time error - controller interface [0x00790001 – Lenze E94AxPExxxx User Manual
Page 680: Violation of time slice [0x00790002, 0x00780009, 0x0078000a, 0x00790000, 0x00790001, 0x00790002, 14 diagnostics & fault analysis

14
Diagnostics & fault analysis
14.7
Error messages of the operating system
680
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Control card is defect (VCC5) [0x00780009]
Electronic nameplate: Data are incompatible [0x0078000a]
Device command transferred incorrectly [0x00790000]
Time error - controller interface [0x00790001]
Violation of time slice [0x00790002]
Module ID (decimal)
Error ID (decimal)
120: Analog signal monitoring
9
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Device error
Consultation with Lenze required.
Module ID (decimal)
Error ID (decimal)
120: Analog signal monitoring
10
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The connected motor with feedback is not supported by
the controller firmware.
Check drive dimensioning.
Module ID (decimal)
Error ID (decimal)
121: Motor data interface
0
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
If the error occurs frequently, please contact Lenze.
Module ID (decimal)
Error ID (decimal)
121: Motor data interface
1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
If the error occurs frequently, please contact Lenze.
Module ID (decimal)
Error ID (decimal)
121: Motor data interface
2
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
If the error occurs frequently, please contact Lenze.