C00059 | motor - number of pole pairs, C00060 | rotor position, C00061 | heatsink temperature – Lenze E94AxPExxxx User Manual
Page 762: C00062 | temperature inside the controller, C00063 | motor temperature, C00064 | device utilisation (ixt), C00064, C00059, C00060, C00063

15
Parameter reference
15.2
Parameter list | C00059
762
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00059
C00060
C00061
C00062
C00063
C00064
Parameter | Name:
C00059 | Motor - number of pole pairs
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display range
(min. value | unit | max. value)
0
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00060 | Rotor position
Data type: INTEGER_32
Index: 24515
d
= 5FC3
h
Display range
(min. value | unit | max. value)
0
2047
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_32
Index: 24514
d
= 5FC2
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00062 | Temperature inside the controller
Data type: INTEGER_32
Index: 24513
d
= 5FC1
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00063 | Motor temperature
Data type: INTEGER_32
Index: 24512
d
= 5FC0
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00064 | Device utilisation (Ixt)
Data type: UNSIGNED_32
Index: 24511
d
= 5FBF
h
Device utilisation during the last 180 seconds
• C00064 > 100 % activates error (OC5).
• Error reset only possible if C00064 < 95 %.
Display range
(min. value | unit | max. value)
0
%
250
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1