C00995 | flying restart: delay time, C00998 | vfc: frequency setpoint, C01120 | sync source – Lenze E94AxPExxxx User Manual
Page 854: C00995, C01120, Ed in, Lected in, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00995
854
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00995
C00998
C01120
Parameter | Name:
C00995 | Flying restart: Delay time
Data type: UNSIGNED_32
Index: 23580
d
= 5C1C
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
10000 0 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00998 | VFC: Frequency setpoint
Data type: INTEGER_32
Index: 23577
d
= 5C19
h
Display range
(min. value | unit | max. value)
-800.0
Hz
800.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C01120 | Sync source
Data type: UNSIGNED_8
Index: 23455
d
= 5B9F
h
Selection of the source for the synchronisation signals.
• The drive can only be synchronised by one source.
Note:
Set the selection "2: CAN module" for the communication module CANopen (E94AYCCA).
"CAN on board" system bus: sync telegram
Selection list
(Lenze setting printed in bold)
0 Off
1 CAN on board
2 CAN module
4 Module in MXI1
5 Module in MXI2
6 Digital input 1
7 Digital input 2
8 Digital input 3
9 Digital input 4
10 Digital input 5
11 Digital input 6
12 Digital input 7
13 Digital input 8
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1